Cap Sheet

STRATACAP PLUS consists of a flexible reinforced 4mm granulated torch-on SBS waterproofing membrane. Particularly developed for low temperature and long-lasting flexibility. The non-woven single-strand polyester fabric gives it high mechanical resistance and superb elasticity.

Developed with a compound of distilled bitumen with a high quantity of thermoplastic rubber which is manufactured from a block of copolymer of radial styrene-butadienestyrene (SBS) which gives it an ultimate elongation of 2,000% and an elastic recovery of 300%. This along with a cold flexibility of -25*C makes this ideal for the varied UK environment. This is considerably superior to ordinary bituminous waterproofing membranes.

Advantages

  • Easily melts when torching
  • Easy and complete jointing
  • Versatile and highly effective waterproofing membrane.
  • Laid on most type of surfaces

Usage

  • Residential and industrial waterproofing
  • Compatible with most materials
  • Suited for single layer on older bituminous roofs or on new build installations

Product Details Back to top

Product Specification

PRODUCT WEIGHT (kg/sqm) DIMENSIONS ROLLS/PALLET
STRATACAP PLUS 4.5kg 1 Roll = 1 x 10m 30

Technical Data

  TECHNICAL DATA   STRATACAP PLUS  
EN Norms Features Units Nominal Values Tolerances
EN 1848-1 LENGTH m 10 > as/declared
EN 1848-1 WIDTH m 1 -0,5%
EN 1848-1 THICKNESS mm 4 ± 0,2
EN 1848-1 WEIGHT kg/m² 4.5  
EN 12311-1

TENSILE STRENGTH long. (max. charge) 

TENSILE STRENGTH trans.(max. charge)

N/50mm

N/50mm

850

700

-20%

-20%

EN 12311-1

ELONGATION AT BREAK longitudinal

ELONGATION AT BREAK transversal

%

%

50

50

-15%

-15%

EN 12310-1

TEARING RESISTANCE longitudinal 

TEARING RESISTANCE transversal

N

N

200

200

 
EN 12730 STATIC PUNCTURING kg 20  
EN 12691 DYNAMIC PUNCTURING mm 800  
EN 1107-1 DIMENSIONAL STABILITY % conforms to UNI 8629  
EN 1109 COLD FLEXIBILITY °C -25   
EN 1110 HEAT RESISTANCE °C 100  
EN 1928 WATER TIGHTNESS Kpa > 60 s
EN 13501-5      EXTERNAL FIRE RESISTANCE                                                      F roof                                                                